---
title: pDS insert set for the Ambr 250 - extend your DoE by scale | p4b
description: "Three 3D-printed inserts with short, medium and long mixing time for Ambr 250 modular and HT vessels. Launch offer 2026: one introductory set per customer."
image: https://www.p4b.io/hubfs/raw_assets/public/p4b/images/og-default.png
---

[![p4b](https://www.p4b.io/hubfs/raw_assets/public/p4b/images/p4b-logo-white.svg) ![p4b](https://www.p4b.io/hubfs/raw_assets/public/p4b/images/p4b-logo-navy.svg)](https://www.p4b.io/?hsLang=en)

Products

[**pDS inserts**Large-scale conditions in your lab bioreactor](https://www.p4b.io/pds?hsLang=en) [**Advanced CFD**Gradients, lifelines and cell experiences](https://www.p4b.io/cfd?hsLang=en) [**DREAM-bio**Find the best geometry for your bioreactor](https://www.p4b.io/dream-bio?hsLang=en) [**Ambr 250 insert set**Three mixing times as a factor in your DoE](https://www.p4b.io/ambr-insert-set?hsLang=en)

[Case studies](https://www.p4b.io/case-studies?hsLang=en) [Insights](https://www.p4b.io/insights?hsLang=en) [Events](https://www.p4b.io/events?hsLang=en) [About](https://www.p4b.io/about?hsLang=en) [Contact](https://www.p4b.io/contact?hsLang=en) [Request a quote](https://www.p4b.io/contact#quote)

pDS insert set · Ambr® 250 modular & HT

# Extend your DoE by scale

Three 3D-printed inserts - short, medium and long mixing time - turn four Ambr® 250 vessels into four scale conditions. Find out how your process reacts to scale before it ever leaves the lab.

[Request your introductory set](https://www.p4b.io/ambr-insert-set#quote)[See the mixing times](https://www.p4b.io/ambr-insert-set#ladder)

**S · M · L**three mixing times in one set

**8 weeks**from order to delivery

**ISO 13485**certified manufacturing

![pDS inserts next to Ambr 250 vessels](https://www.p4b.io/hubfs/website/pds-family.webp)

Launch offer 2026

**One introductory set per customer at a launch price.** Order by 31 December 2026 - delivery within 8 weeks. Price on request.

[Request your set →](https://www.p4b.io/ambr-insert-set#quote)

What's in the set

## One set, four scale conditions

Run your standard vessel as the lab reference and one vessel with each insert. Same stirrer, same probes, same control strategy - only the mixing time changes.

SetAmbr® 250 - standard vessel plus inserts S, M and L*mixing time, gassed*

Your standard vessel

### Lab reference

Fast mixing, homogeneous conditions - your current baseline. **≈ 5 s**

pDS insert S

### Short mixing time

The first step towards large-scale mixing - the same with or without gassing. **≈ 29 s**

pDS insert M

### Medium mixing time

Within the range published for 2,000 L single-use tanks. **≈ 42 s**

pDS insert L

### Long mixing time

The slow end of large-scale mixing. **≈ 76 s**

- See which parameters are sensitive to scale
- Find operating windows that hold at production scale
- Fix issues while they are still cheap to fix

### Included

- 1 × insert S, 1 × insert M, 1 × insert L
- Nylon, single use - made by our ISO 13485-certified manufacturing partner, certificate included
- Data sheet with the mixing times of all three inserts - CFD and pH-indicator measurement
- Step-by-step guide for autoclaving and fitting

### Fits your Ambr® 250

- Ambr® 250 modular and Ambr® 250 HT vessels
- You keep your standard vessel - the insert simply goes inside; ports, probes and sparger stay as they are
- Mixing times measured at 350 rpm with 200 mL, with and without gassing
- Fitted under the laminar flow hood in about five minutes, no tools - [watch the video →](https://www.p4b.io/ambr-insert-set#assembly)

Mixing times

## From lab mixing to large-scale mixing

Measured in the Ambr® 250 with a pH indicator: time until 95 % of the liquid has reached its final colour, at 350 rpm with 200 mL and 0.15 vvm, acid added through the feed line. For comparison: mixing times published for large single-use tanks.

Ambr® 250, standard

5 s

\+ insert S

29 s

\+ insert M

42 s

\+ insert L

76 s

200 L single-use (published)

12 s

2,000 L single-use (published)

30-65 s

Ambr® 250 gassed with 0.15 vvm, as in a running culture; scale 0-80 s. Without gas: 4, 26, 39 and 51 s. Large tanks: published manufacturer characterizations and peer-reviewed measurements at 5-28 W/m³, mostly without gas; methods differ, so compare orders of magnitude. The set does not copy one tank - it adds scale as a factor to your DoE.

Example structures from design runs - not the product inserts.

![3D-printed pDS inserts next to Ambr 250 vessels](https://www.p4b.io/hubfs/website/pds-family.webp)

Loading 3D model…

Structure - slows down mixing

Original stirrer & headplate

Standard Ambr® 250 vessel

Standard

S

M

L

Cross-section

Drag to rotate

**≈ 5 s**Standard Ambr® 250 - fast mixing, homogeneous conditions. Your lab reference.

**≈ 29 s**Insert S - short mixing time, the same with or without gassing.

**≈ 42 s**Insert M - medium mixing time, within the range published for 2,000 L single-use tanks.

**≈ 76 s**Insert L - long mixing time, the slow end of large-scale mixing.

The structure divides the vessel into zones that exchange liquid slowly. Stirrer, probes, sparger and control strategy stay unchanged - from S to L only the mixing time grows.

[Request your set →](https://www.p4b.io/ambr-insert-set#quote)

How it works

## From the box to your scale-down DoE

01 · Order

Request your set. We confirm the price and the delivery date - within 8 weeks after your order.

02 · Autoclave & fit

Autoclave the inserts, then fit them into your pre-sterilised Ambr® 250 vessels under the laminar flow hood - about five minutes, no tools.

03 · Run your DoE

Standard vessel, S, M and L in parallel - one more factor in your design: scale. Everything else stays as you run it today.

04 · Read out scale effects

Compare growth, metabolites and product quality across the four conditions and see which of them are sensitive to scale.

Fitting an insert into an Ambr® 250 vessel under the laminar flow hood - about five minutes, no tools.

Results with pDS inserts

## What cells do when mixing slows down

Cultures run with pDS inserts - in our own lab and with partners.

![pDS inserts next to Ambr 250 vessels](https://www.p4b.io/hubfs/website/pds-family.webp)

Preprint · Satzer et al. · CHO

### 10,000 L conditions in a 1 L vessel

Lactate and mAb titer in a CHO process under large-scale gradients, reproduced at bench scale with a pDS insert.

Preprint coming soon

### [![pDS reactors in the lab at the Max Planck Institute](https://www.p4b.io/hubfs/website/insights/mpi-lab.webp) Peer-reviewed · Vaccines 2025 · MPI Zika vaccine production at two scales Göbel, Genzel et al. used pDS vessels to mimic process conditions of two scales at bench scale and studied how viral sensitizers affect the yield of a YF17D-vectored Zika vaccine. Read the article →](https://www.mdpi.com/2076-393X/13/7/757)

## Request your introductory set

Launch offer 2026

### One introductory set per customer

- Launch price - sent with your offer
- Order by 31 December 2026
- Delivery within 8 weeks

### Your contact

![Lena Achleitner](https://www.p4b.io/hs-fs/hubfs/website/team/lena-avatar.webp?width=64&height=64&name=lena-avatar.webp)

**Lena Achleitner**Senior Bioprocess Engineer, Key Account Manager[lena.achleitner@p4b.io](mailto:lena.achleitner@p4b.io)

### Rather talk first?

30 minutes with our team - for your Process Development or MSAT team.

[Pick a time →](https://meetings-eu1.hubspot.com/manfred-satzer/p4b-round-robin-calender)

FAQ

## Questions about the set

Which Ambr® 250 vessels does the set fit?

Both the Ambr® 250 modular and the Ambr® 250 HT vessels. You keep your standard vessel and simply place the insert inside - ports, probes and sparger stay exactly where they are.

What do short, medium and long stand for?

Three steps of mixing time between the standard Ambr® 250 (about 5 s) and large production reactors: at 350 rpm and 0.15 vvm about 29, 42 and 76 s until 95 % of the liquid is mixed (without gas 26, 39 and 51 s). Published values for 2,000 L single-use tanks lie between 30 and 65 s. The set does not copy one specific tank - it makes scale a factor in your DoE, next to temperature, pH and feed.

Do the inserts add shear?

Only a little. In the CFD, the shear with insert stays close to the empty Ambr® 250 and in the same range as a 200 L single-use tank. Gas bubbles bursting at the surface remain the main source of hydrodynamic stress, as in any sparged Ambr® culture.

At which stirrer speed?

At the stirrer speeds you already use in the Ambr® 250. Mixing gets slower at lower speed and with gassing, as in any bioreactor. Running unusual conditions? Let's talk before you order.

Does anything stick to the insert?

No - we have seen no build-up in E. coli, CHO or stem cell cultures. Filamentous fungi have not been tested yet; if that is your system, we would like to test it together with you.

How is the insert sterilised - is it reusable?

Inserts are made of nylon and single use. You autoclave them and fit them into the pre-sterilised Ambr® 250 vessel under the laminar flow hood. They are made by our ISO 13485-certified manufacturing partner; the certificate comes with every delivery.

I need more than one set - is that possible?

The launch offer covers one introductory set per customer. For replicates or a full 24-vessel campaign, ask us for a quote for additional sets.

Does the set replace runs at production scale?

It brings scale into your Ambr® screening. You see early which parameters react to scale and can adjust them while changes are still cheap, so your large-scale runs start from a scale-aware process and confirm instead of surprise.

### Get new insights by email

CFD results, case studies and new insert systems when we publish them. Unsubscribe any time.

![p4b](https://www.p4b.io/hubfs/raw_assets/public/p4b/images/p4b-logo-white.svg)

Scale reliably. Develop faster.  
Digital and 3D-printed technologies for bioprocessing.

[Follow us on LinkedIn](https://www.linkedin.com/company/p4b-gmbh/)

#### Products

- [pDS inserts](https://www.p4b.io/pds?hsLang=en)
- [Advanced CFD](https://www.p4b.io/cfd?hsLang=en)
- [DREAM-bio](https://www.p4b.io/dream-bio?hsLang=en)
- [Request a quote](https://www.p4b.io/contact#quote)

#### Company

- [About us](https://www.p4b.io/about?hsLang=en)
- [Case studies](https://www.p4b.io/case-studies?hsLang=en)
- [Insights](https://www.p4b.io/insights?hsLang=en)
- [Events](https://www.p4b.io/events?hsLang=en)
- [Contact](https://www.p4b.io/contact?hsLang=en)

#### Contact

**Office & deliveries**  
p4b GmbH  
Leopold-Ungar-Platz 2  
Spaces Square One, Stiege 2  
1190 Vienna, Austria

[+43 677 61062225](tel:+4367761062225)  
[office@p4b.io](mailto:office@p4b.io)

Registered office: Gärtnersteg 4, 2120 Obersdorf, Austria

Supported by ![austria wirtschaftsservice](https://www.p4b.io/hubfs/raw_assets/public/p4b/images/logos/aws.png) ![Bundesministerium Arbeit und Wirtschaft](https://www.p4b.io/hubfs/raw_assets/public/p4b/images/logos/bmaw.png) ![Bundesministerium Klimaschutz, Umwelt, Energie, Mobilität, Innovation und Technologie](https://www.p4b.io/hubfs/raw_assets/public/p4b/images/logos/bmk.png) ![FFG](https://www.p4b.io/hubfs/raw_assets/public/p4b/images/logos/ffg.png)

© 2026 p4b GmbH · FN 611768i · ATU79846712

[Imprint](https://www.p4b.io/imprint?hsLang=en)[Privacy policy](https://www.p4b.io/privacy-policy?hsLang=en)Cookie settings

```json
{
  "@context" : "https://schema.org",
  "@type" : "Organization",
  "address" : {
    "@type" : "PostalAddress",
    "addressCountry" : "AT",
    "addressLocality" : "Obersdorf",
    "postalCode" : "2120",
    "streetAddress" : "Gärtnersteg 4"
  },
  "description" : "Scale-down technology for bioprocess development: 3D-printed pDS inserts, bioreactor CFD and DREAM-bio design optimisation.",
  "email" : "office@p4b.io",
  "logo" : "//143831650.fs1.hubspotusercontent-eu1.net/hubfs/143831650/raw_assets/public/p4b/images/p4b-logo-navy.svg",
  "name" : "p4b GmbH",
  "sameAs" : [ "https://www.linkedin.com/company/p4b-gmbh/" ],
  "telephone" : "+43 677 61062225",
  "url" : "https://www.p4b.io"
}
```

```json
{
  "@context" : "https://schema.org",
  "@type" : "FAQPage",
  "mainEntity" : [ {
    "@type" : "Question",
    "acceptedAnswer" : {
      "@type" : "Answer",
      "text" : "Both the Ambr® 250 modular and the Ambr® 250 HT vessels. You keep your standard vessel and simply place the insert inside - ports, probes and sparger stay exactly where they are."
    },
    "name" : "Which Ambr® 250 vessels does the set fit?"
  }, {
    "@type" : "Question",
    "acceptedAnswer" : {
      "@type" : "Answer",
      "text" : "Three steps of mixing time between the standard Ambr® 250 (about 5 s) and large production reactors: at 350 rpm and 0.15 vvm about 29, 42 and 76 s until 95 % of the liquid is mixed (without gas 26, 39 and 51 s). Published values for 2,000 L single-use tanks lie between 30 and 65 s. The set does not copy one specific tank - it makes scale a factor in your DoE, next to temperature, pH and feed."
    },
    "name" : "What do short, medium and long stand for?"
  }, {
    "@type" : "Question",
    "acceptedAnswer" : {
      "@type" : "Answer",
      "text" : "Only a little. In the CFD, the shear with insert stays close to the empty Ambr® 250 and in the same range as a 200 L single-use tank. Gas bubbles bursting at the surface remain the main source of hydrodynamic stress, as in any sparged Ambr® culture."
    },
    "name" : "Do the inserts add shear?"
  }, {
    "@type" : "Question",
    "acceptedAnswer" : {
      "@type" : "Answer",
      "text" : "At the stirrer speeds you already use in the Ambr® 250. Mixing gets slower at lower speed and with gassing, as in any bioreactor. Running unusual conditions? Let's talk before you order."
    },
    "name" : "At which stirrer speed?"
  }, {
    "@type" : "Question",
    "acceptedAnswer" : {
      "@type" : "Answer",
      "text" : "No - we have seen no build-up in E. coli, CHO or stem cell cultures. Filamentous fungi have not been tested yet; if that is your system, we would like to test it together with you."
    },
    "name" : "Does anything stick to the insert?"
  }, {
    "@type" : "Question",
    "acceptedAnswer" : {
      "@type" : "Answer",
      "text" : "Inserts are made of nylon and single use. You autoclave them and fit them into the pre-sterilised Ambr® 250 vessel under the laminar flow hood. They are made by our ISO 13485-certified manufacturing partner; the certificate comes with every delivery."
    },
    "name" : "How is the insert sterilised - is it reusable?"
  }, {
    "@type" : "Question",
    "acceptedAnswer" : {
      "@type" : "Answer",
      "text" : "The launch offer covers one introductory set per customer. For replicates or a full 24-vessel campaign, ask us for a quote for additional sets."
    },
    "name" : "I need more than one set - is that possible?"
  }, {
    "@type" : "Question",
    "acceptedAnswer" : {
      "@type" : "Answer",
      "text" : "It brings scale into your Ambr® screening. You see early which parameters react to scale and can adjust them while changes are still cheap, so your large-scale runs start from a scale-aware process and confirm instead of surprise."
    },
    "name" : "Does the set replace runs at production scale?"
  } ]
}
```